Journal of Oral and Maxillofacial Radiology

ORIGINAL ARTICLE
Year
: 2019  |  Volume : 7  |  Issue : 2  |  Page : 21--24

Audit of the quality of intraoral periapical radiograph: An institutional study


Sunita Shankarrao Patankar, Freny R Karjodkar, Kaustubh P Sansare, Shalvi Vora 
 Department of Oral Medicine and Radiology, Nair Hospital Dental College, Mumbai, Maharashtra, India

Correspondence Address:
Sunita Shankarrao Patankar
Department of Oral Medicine and Radiology, Nair Hospital Dental College, Mumbai, Maharashtra
India

Objectives: To reduce the radiation exposure to patients, to improve the diagnostic proficiency of radiographs, and to collect data which will help decide the action of improvement in performance. Materials and Methods: The audit consisted of two cycles: Audit Cycle 1 analyzed randomly selected 400 recently taken intraoral periapical (IOPA) radiograph and the quality of each film was recorded according to subjective quality rating of radiograph given by the national board of radiation protection (NPRB) guidance and put them into Grades 1, 2, or 3. Audit Cycle 2 radiographs from Grades 2 and 3 were further randomly reevaluated to determine the causes of error and these are classified into faults due to positioning, exposure, and chemical processing. Frequency (n) and percentage (%) of outcome of various grades overall and with respect to independent variables will be compared using Chi-square test. Results: Of the 400 IOPA radiographs, 180 (45%) score Grade 1, 165 (41.3%) score Grade 2, and 55 (13.8%) score Grade 3. In Grade 2, IOPA radiographs of 163 (40.7%) were found to be positioning error, 45 (11.2%) exposure error, and 9 (5.5%) chemical processing. In Grade 3 (out of 57 IOPA), radiographs were rejected due to positioning faults in 45 (28.8%), exposure error in 7 (4.3%), and chemical processing in 3 (1.8%). Conclusion: The overall quality of radiographs was not found to be satisfactory when compared with standard recommendations of the National Board of Radiation Protection of UK. When the audit of the quality was done at regular intervals, it can be used as a guide to effective dose reduction and reduction of unnecessary irradiation of the patients and staff.


How to cite this article:
Patankar SS, Karjodkar FR, Sansare KP, Vora S. Audit of the quality of intraoral periapical radiograph: An institutional study.J Oral Maxillofac Radiol 2019;7:21-24


How to cite this URL:
Patankar SS, Karjodkar FR, Sansare KP, Vora S. Audit of the quality of intraoral periapical radiograph: An institutional study. J Oral Maxillofac Radiol [serial online] 2019 [cited 2020 Feb 29 ];7:21-24
Available from: http://www.joomr.org/article.asp?issn=2321-3841;year=2019;volume=7;issue=2;spage=21;epage=24;aulast=Patankar;type=0